PI Engineering Inc.

Lightning Notification System Units

Inside Unit

Applications

  •  Warn Staff members in break rooms and offices of lightning storms
  • Get’s accurate, up-to-date storm information over wifi to keep staff up to date on Storm and lightning threats
  • Has two warning levels based on storm distance from location
  • Can be controlled manually in case of emergency via touch screen control panel

Features

Tower Beacons

  • Voltage: 230 VAC
  • Voltage Type: AC
  • Voltage Frequency: 50Hz
  • Voltage Tolerance: +/-20%
  • Operational Voltage: 230 VAC
  • Operational Current: 40mA
  • Isolation Voltage: Ui= 250V; Uimp=2500V
  • Max-Min functionable Temperatures: 10°C-35°C
  • Service Life: 50,000 hour

Tower Horn

  • Voltage: 230VAC
  • Voltage Type: AC
  • Voltage Frequency: 50Hz
  • Voltage Tolerance: +/-10%
  • Operational Voltage:230 VAC
  • Operational Current: 24 mA
  • Inrush Current: 1500mA
  • Isolation Voltage: Ui=250V; Uimp= 2.500V
  • Max Volume at 1m Distance: 85,0 dB (A))
  • Audio Frequency: 3.500 Hz
  • Max-Min Functional Temperature: -20°C-50°C
  • Service Life: 5,000 hours

Power Supply

  • 96W AC/DC
  • Input: 90 VAC, 264 VAC
  • Output: 13.8VDC and 27.6VDC
  • Battery reverse polarity protection
  • Battery low protection
  • Voltage Range: 90-264VAC 127-370VDC
  • Frequency Range: 47-63Hz
  • Efficiency: 89%
  • AC Current: 1.8A/115VAC 1.1A/230VAC
  • Inrush Current: COLD START 30A/115VAC 60A/230VAC

Description

Indoor Units utilize a tower beacon and horn system on top of a components box to alert  staff of near by lightning danger. It get’s up to date weather information over the network via wifi and can be installed in most offices and breakrooms. 

Outside Unit

Applications

  •  Warn Staff members in outside facilities of nearby lightning storms
  • Get’s accurate, up-to-date storm information over wifi to keep staff up to date on Storm and lightning threats
  • Has two warning levels based on storm distance from location
  • Can be controlled manually in case of emergency via touch screen control panel

Features

Beacons

  • 12-24 VDC, 2.1 Amps, 75/125 FPM
  • 1 Flash pattern 2 different rotating speeds; 70 at 75FPM and 120 at 125FPM
  • gearless, brush-less, and bulb-less
  •  8 high intensity LEDs with TIR optic
  • UV hard coated  lens to greatly reduce cracking, hazing, abrasion and fading
  • Simple mounting
  • Temperature range: -22°F to 122°F (-30°C-50°C)

Horn

  • Rating: IP66
  • Current Type: DC
  • Base Length: 166.3 mm
  • Housing Material: PC
  • Max-Min Functional Temperatures: -25°C-70°C
  • Supply Voltage: 10 to 60 VDC
  • Max Volume at 1 meter: 120DB

Power Supply

  • IP67/IP65 rating
  • Typical lifetime: 62,000 hours
  • 90-305VAC voltage
  • Able to operate in -40°C – 90°C
  • Voltage Range: 90-305 VAC, 127-431 VDC
  • Frequency Range: 47 -63 Hz
  • Power Factor: PF ≥ 0.98/115 VAC, PF ≥ 0.95/230 VAC
  • Total Harmonic Distortion: THD<20% (@load≥50%/115VAC, 230VAC; @load≥75%/277VAC)
  • Efficiency: 92.5%
  • AC Current: 4A/115VAC 2A/230VAC 1.2A/277VAC
  • Inrush Current: Cold Start 75A (twidth=570μS measured at 50% lpeak) at 230VAC;Per NEMA 410
  • MAX number of PSUs on 16A Circuit Breaker: 2 Units (circuit breaker of type B)/4 units (circuit breaker of type C) at 230VAC
  • Leakage Current: <0.75mA/277VAC
  • Working Temperature: Tcase=-40-+90°C (Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
  • MAX Case Temperature: Tcase= +90°C
  • Working Humidity: 20-95% RH non-condensing
  • Storage Temperature Humidity: -40-+80°C, 10-95% RH
  • Temperature Coefficient: ±0.03%°C (0-50°C)
  • Vibration: 10-500Hz, 5G 12 min./1cycle, period for 72min. each along X,Y,Z axes

Frame: Misumi

  • Standard Extrusion Size: 30 mm
  • Surface Finish: Clear Anodize
  • Material: A6N01SS-T5 Aluminum Alloy

Description